Anchor Point Testing & Installation

Keep Your Workers Safe and Your Business Compliant

REQUEST A QUOTE

Professional load testing & Anchor Installation In Sydney

At Integrity Projects, we deliver comprehensive anchor point testing and installation services for high-rise buildings across Sydney. Using IRATA rope access and certified testing equipment, we inspect, load test, and certify your fall protection anchors to AS/NZS 1891.4 standards — ensuring worker safety and legal compliance without scaffolding or building disruption.

20+ Years Experience In

Professional anchor point testing isn't just about ticking boxes — it's about protecting lives, avoiding prosecution, and maintaining insurance coverage when accidents happen.

Inspection

Anchor Testing & Documentation

Facility management

Annual Testing & Maintenance

Shield

Compliant With AS/NZS 1891.4

What We Test & Install

Fall Arrest Anchor Points

  • Purpose: Stop workers who have already started to fall
  • Load Testing: Minimum 15kN (1,500kg) static load test
  • Applications: Roof work, facade maintenance, general height access
  • Certification: Annual inspection and testing required by AS/NZS 1891.4

Fall Restraint Anchor Points

  • Purpose: Prevent workers from reaching fall hazard areas
  • Load Testing: Minimum 12kN (1,200kg) static load test
  • Applications: Roof edge work, equipment maintenance areas
  • Certification: Annual inspection, load testing when concrete-fixed

Abseil/Rope Access Anchors

  • Purpose: Support controlled descent and positioning work
  • Load Testing: Minimum 15kN static, dynamic testing when required
  • Applications: Building maintenance, inspection access, cleaning operations
  • Certification: 12-monthly inspection and testing mandatory

Why Australian Buildings Need Anchor Points

Legal Requirements:

  • Work Health and Safety Act duty of care obligations
  • AS/NZS 1891 fall protection system requirements
  • Building Code of Australia maintenance access provisions

     

Who’s Responsible:

  • Building Owners: Ultimate responsibility for providing safe access systems
  • Controllers of Workplaces: Must ensure anchor systems are available and compliant
  • Employers: Responsible for using appropriate anchor points for worker protection

Our Installation Process

  1. Site Assessment & Design
    Structural assessment, anchor positioning, and load path analysis
  2. Engineering Certification
    Calculations and drawings by qualified structural engineers
  3. Professional Installation
    Installation by certified technicians using AS/NZS 5532 methods
  4. Load Testing & Certification
    Full testing and compliance documentation upon completion
  5.  Handover Documentation
    Complete records for building files and maintenance planning
Corporation

Building Owners & Strata Managers

Meet your legal duty of care obligations and protect against prosecution if accidents occur.

Facility management

Facility Managers

Ensure contractor safety and maintain building insurance requirements with compliant anchor systems.

Residential

Construction Companies

Get new anchor installations tested and certified for handover and compliance documentation

Hotel

Maintenance Contractors

Work safely with confidence knowing anchor points are properly tested and certified.

Why Anchor Testing Matters for Your Business

What You Receive From Us

REQUEST A QUOTE

0422 222 324

Protect your workers, meet legal requirements, and avoid prosecution with professional anchor point testing.

No Guess Work

Our High-rise Anchor Testing & Installation Process

1
Visual Inspection

Assess anchor condition, check for corrosion, confirm substrate integrity, and verify marking compliance.

2
Load Testing

Apply calibrated static loads with precise measurement to test anchor strength.

3
Assessment & Tagging

Record pass/fail results against AS/NZS 1891.4 standards, tag compliant anchors, and mark non-compliant anchors “DO NOT USE.”

4
Certification & Documentation

 Issue 12-month compliance certificates, provide detailed roof anchor diagrams, and record all results for audit compliance.

Why Choose Integrity Projects For Your Anchor Maintenance?

Certified Testing Specialists — IRATA rope access technicians with calibrated load testing equipment

Legal Compliance Focus — Complete AS/NZS 1891.4 documentation meeting regulatory requirements

Professional Installation — New anchor points designed and installed to AS/NZS 5532 standards

Comprehensive Reporting — Detailed documentation for legal protection and insurance compliance

Risk Management — Immediate safety actions for failed anchors and replacement planning

Katsafe Accredited Installer — Certified installation and testing of Katsafe (formerly SAYFA) height safety systems

Zero Building Disruption — Rope access testing without scaffolding or operational shutdown

Frequently Asked Questions

How often do anchor points need to be tested?

Minimum 12 months for most applications, but some states require 6-monthly testing. Harsh environments need more frequent inspection.

We immediately tag it “DO NOT USE,” document the failure, and provide replacement recommendations with pricing.

 We can test in most conditions but may postpone during severe weather for safety reasons.

Fall arrest (15kN minimum) catches workers who fall. Fall restraint (12kN minimum) prevents reaching fall hazards.

Yes, but concrete anchors need curing time. We schedule testing after proper cure periods.

12-month certificates, detailed roof diagrams and individual anchor records.

Didn’t find your answer? Our team is here to help — get in touch today!

REQUEST A QUOTE

Get Compliant Anchor Point Testing

Don’t risk worker safety or business liability with uncertified anchor points. Get professional testing and documentation that stands up to regulatory scrutiny.

DISCOVER A RANGE OF SERVICES PROVIDED BY US AT HEIGHT.

Integrity projects are fully insured for public liability with $20 million coverage and work cover applys for all our team members.

Unnamed 4 removebg preview
MBuilders Member logo removebg preview

REPAIR & MAINTENANCE

BUILDING CLEANING

HEIGHT SAFETY SYSTEMS

OUR FEATURED PROJECTS & CASE STUDYS

HAVE A

PROJECT

NEEDING

ABSEILING?